Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 187
Filtrar
3.
Gen Thorac Cardiovasc Surg ; 69(1): 147-150, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32920748

RESUMEN

Tumor-to-tumor metastasis is a rare phenomenon. We present a rare case of an 83-year-old man with pulmonary squamous cell carcinoma and thymoma. Thymectomy and superior segmentectomy of the left lower lobe were successfully performed on the patient. This thymoma had a region of lung cancer. Metastasis from other tumors to thymoma is rare, and we found a report that described a pancreatic carcinoma metastasizing to thymoma. We report an extremely rare case of metastasis from lung cancer to a thymoma.


Asunto(s)
Neoplasias Pulmonares , Timoma , Neoplasias del Timo , Anciano de 80 o más Años , Humanos , Neoplasias Pulmonares/cirugía , Masculino , Timectomía , Timoma/cirugía , Neoplasias del Timo/cirugía
6.
Phys Rev Lett ; 119(18): 182503, 2017 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-29219585

RESUMEN

The gamma strength function and level density of 1^{-} states in ^{96}Mo have been extracted from a high-resolution study of the (p[over →], p[over →]^{'}) reaction at 295 MeV and extreme forward angles. By comparison with compound nucleus γ decay experiments, this allows a test of the generalized Brink-Axel hypothesis in the energy region of the pygmy dipole resonance. The Brink-Axel hypothesis is commonly assumed in astrophysical reaction network calculations and states that the gamma strength function in nuclei is independent of the structure of the initial and final state. The present results validate the Brink-Axel hypothesis for ^{96}Mo and provide independent confirmation of the methods used to separate gamma strength function and level density in γ decay experiments.

8.
Leukemia ; 31(1): 203-212, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27349810

RESUMEN

Dasatinib treatment markedly increases the number of large granular lymphocytes (LGLs) in a proportion of Ph+ leukemia patients, which associates with a better prognosis. The lymphocytosis is predominantly observed in cytomegalovirus (CMV)-seropositive patients, yet detectable CMV reactivation exists only in a small fraction of patients. Thus, etiology of the lymphocytosis still remains unclear. Here, we identified NK cells as the dominant LGLs expanding in dasatinib-treated patients, and applied principal component analysis (PCA) to an extensive panel of NK cell markers to explore underlying factors in NK cell activation. PCA displayed phenotypic divergence of NK cells that reflects CMV-associated differentiation and genetic differences, and the divergence was markedly augmented in CMV-seropositive dasatinib-treated patients. Notably, the CMV-associated highly differentiated status of NK cells was already observed at leukemia diagnosis, and was further enhanced after starting dasatinib in virtually all CMV-seropositive patients. Thus, the extensive characterization of NK cells by PCA strongly suggests that CMV is an essential factor in the NK cell activation, which progresses stepwise during leukemia and subsequent dasatinib treatment most likely by subclinical CMV reactivation. This study provides a rationale for the exploitation of CMV-associated NK cell activation for treatment of leukemias.


Asunto(s)
Citomegalovirus , Dasatinib/uso terapéutico , Células Asesinas Naturales/inmunología , Leucemia Mielógena Crónica BCR-ABL Positiva/inmunología , Análisis de Componente Principal , Humanos , Células Asesinas Naturales/microbiología , Leucemia Mielógena Crónica BCR-ABL Positiva/tratamiento farmacológico , Activación Viral
9.
Rev Sci Instrum ; 87(2): 02B928, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26932100

RESUMEN

Recently, several developments of low energy beam transport line and its beam diagnostic systems have been performed to improve the injection efficiency of ion beam to azimuthally varying field cyclotron at Research Center for Nuclear Physics, Osaka University. One of those is the fast emittance monitor which can measure within several seconds for the efficient beam development and a Pepper-Pot Emittance Monitor (PPEM) has been developed. The PPEM consists of pepper-pot mask, multichannel plate, fluorescent screen, mirror, and CCD camera. The CCD image is taken via IEEE1394b to a personal computer and analyzed immediately and frequently, and then real time measurement with about 2 Hz has been achieved.

10.
Appl Opt ; 55(5): 1164-9, 2016 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-26906392

RESUMEN

We demonstrate frequency offset locking between two laser sources using a waveguide-type electro-optic modulator (EOM) with 10th-order sidebands for magneto-optical trapping of Fr atoms. The frequency locking error signal was successfully obtained by performing delayed self-homodyne detection of the beat signal between the repumping frequency and the 10th-order sideband component of the trapping light. Sweeping the trapping-light and repumping-light frequencies with keeping its frequency difference of 46 GHz was confirmed over 1 GHz by monitoring the Doppler absorption profile of I2. This technique enables us to search for a resonance frequency of magneto-optical trapping of Fr.

12.
J Periodontal Res ; 51(3): 321-31, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26251312

RESUMEN

BACKGROUND AND OBJECTIVE: The biochemical effects of an over-the-counter (OTC) medication were studied, which consists of a single-tuft brush containing cetylpyridinium chloride as a bactericidal agent, dipotassium glycyrrhizate as an anti-inflammatory drug and allantoin as a promoter of cell proliferation and wound healing, for delivery to hardly brushed sites. MATERIAL AND METHODS: This randomized controlled double-blind study was performed in 61 subjects with chronic periodontitis in supportive periodontal therapy phase (test group: n = 27; placebo group: n = 28; dropout: n = 6). The OTC medication was self-applied twice a day for 12 wk to two molars with probing pocket depths of 4-6 mm. Biochemical indicators were evaluated at baseline and 12 wk using the suspension array system for eight cytokines and chemokines (interleukin [IL]-1ß, IL-1ra, IL-4, IL-6, IL-8, IL-10, monocyte chemoattractant protein-1 and tumor necrosis factor [TNF]-α) in gingival crevicular fluid. RESULTS: The levels of IL-1ß, IL-6, IL-8 and TNF-α remained significantly lower in the test group compared to the placebo group. In the placebo group, when the probing pocket depth at baseline was 4 mm, IL-1ß increased, particularly in the second molar tooth, and the greatest increase was seen when PPD at baseline was 5-6 mm. In the test group, IL-1ß decreased markedly in cases with furcation involvement and low bleeding on probing at baseline. In both groups, IL-1ß, IL-6 and TNF-α were closely correlated with each other. CONCLUSION: This OTC medication is biochemically effective for steady chronic periodontitis in the supportive periodontal therapy phase.


Asunto(s)
Quimiocinas/efectos de los fármacos , Periodontitis Crónica/tratamiento farmacológico , Citocinas/efectos de los fármacos , Líquido del Surco Gingival/efectos de los fármacos , Medicamentos sin Prescripción/uso terapéutico , Bases Oleosas/uso terapéutico , Anciano , Alantoína/uso terapéutico , Cetilpiridinio/uso terapéutico , Quimiocina CCL2/análisis , Quimiocinas/análisis , Citocinas/análisis , Índice de Placa Dental , Método Doble Ciego , Esquema de Medicación , Femenino , Ácido Glicirrínico/uso terapéutico , Humanos , Proteína Antagonista del Receptor de Interleucina 1/análisis , Interleucina-10/análisis , Interleucina-1beta/análisis , Interleucina-4/análisis , Interleucina-6/análisis , Interleucina-8/análisis , Japón , Masculino , Persona de Mediana Edad , Pérdida de la Inserción Periodontal , Índice Periodontal , Cepillado Dental/instrumentación , Factor de Necrosis Tumoral alfa/análisis
13.
Phys Rev Lett ; 115(10): 102501, 2015 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-26382672

RESUMEN

Differential cross sections of isoscalar and isovector spin-M1 (0(+)→1(+)) transitions are measured using high-energy-resolution proton inelastic scattering at E(p)=295 MeV on (24)Mg, (28)Si, (32)S, and (36)Ar at 0°-14°. The squared spin-M1 nuclear transition matrix elements are deduced from the measured differential cross sections by applying empirically determined unit cross sections based on the assumption of isospin symmetry. The ratios of the squared nuclear matrix elements accumulated up to E(x)=16 MeV compared to a shell-model prediction are 1.01(9) for isoscalar and 0.61(6) for isovector spin-M1 transitions, respectively. Thus, no quenching is observed for isoscalar spin-M1 transitions, while the matrix elements for isovector spin-M1 transitions are quenched by an amount comparable with the analogous Gamow-Teller transitions on those target nuclei.

14.
Br J Cancer ; 111(7): 1363-72, 2014 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-25077440

RESUMEN

BACKGROUND: Epithelial-mesenchymal transition (EMT) is characterised by the loss of cell-to-cell adhesion and gaining of mesenchymal phenotypes. Epithelial-mesenchymal transition is proposed to occur in various developmental processes and cancer progression. 'Cadherin switch', a process in which cells shift to express different isoforms of the cadherin transmembrane protein and usually refers to a switch from the expression of E-cadherin to N-cadherin, is one aspect of EMT and can have a profound effect on tumour invasion/metastasis. The aim of this study was to investigate the clinicopathological significance of EMT-related proteins and cadherin switch in extrahepatic cholangiocarcinoma (EHCC). METHODS: We investigated the association between altered expression of 12 EMT-related proteins and clinical outcomes in patients with EHCC (n=117) using immunohistochemistry on tissue microarrays. RESULTS: Univariate and multivariate analyses revealed that, in addition to N classification (P=0.0420), the expression of E-cadherin (P=0.0208), N-cadherin (P=0.0038) and S100A4 (P=0.0157) was each an independent and a significant prognostic factor. We also demonstrated that cadherin switch was independently associated with poor prognosis (P=0.0143) in patients with EHCC. CONCLUSIONS: These results may provide novel information for selection of patients with EHCC who require adjuvant therapy and strict surveillance.


Asunto(s)
Neoplasias de los Conductos Biliares/patología , Conductos Biliares Extrahepáticos/metabolismo , Conductos Biliares Intrahepáticos/metabolismo , Biomarcadores de Tumor/metabolismo , Colangiocarcinoma/patología , Transición Epitelial-Mesenquimal , Adulto , Anciano , Anciano de 80 o más Años , Antígenos CD/metabolismo , Neoplasias de los Conductos Biliares/metabolismo , Neoplasias de los Conductos Biliares/mortalidad , Conductos Biliares Extrahepáticos/patología , Conductos Biliares Intrahepáticos/patología , Cadherinas/metabolismo , Línea Celular Tumoral , Colangiocarcinoma/metabolismo , Colangiocarcinoma/mortalidad , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Pronóstico , Análisis de Matrices Tisulares
15.
Phys Rev Lett ; 112(11): 112502, 2014 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-24702355

RESUMEN

Gamow-Teller (GT) transitions in atomic nuclei are sensitive to both nuclear shell structure and effective residual interactions. The nuclear GT excitations were studied for the mass number A = 42, 46, 50, and 54 "f-shell" nuclei in ((3)He, t) charge-exchange reactions. In the (42)Ca → (42)Sc reaction, most of the GT strength is concentrated in the lowest excited state at 0.6 MeV, suggesting the existence of a low-energy GT phonon excitation. As A increases, a high-energy GT phonon excitation develops in the 6-11 MeV region. In the (54)Fe → (54)Co reaction, the high-energy GT phonon excitation mainly carries the GT strength. The existence of these two GT phonon excitations are attributed to the 2 fermionic degrees of freedom in nuclei.

16.
Rev Sci Instrum ; 85(2): 02A732, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24593466

RESUMEN

The search for the violation of the fundamental symmetry in a radioactive atom is the promising candidate for precision tests of the standard model and its possible extensions. The subtle signal arising from the symmetry violation is enhanced in heavy atoms, such as a francium (Fr). To realize high precision measurements, a large amount of radioactive isotopes is required. The Fr is produced via a nuclear fusion reaction using a melted gold target with a (18)O primary beam at Cyclotron and Radioisotope Center, Tohoku University. The maximum extraction efficiency of the Fr ion was achieved at approximately 35%. The beam line consists of an electrostatic deflector, three electrostatic quadrupole triplets to the measurement area at 10 m away from the reaction point, and several beam diagnosis systems. We optimized parameters of the beam line.

17.
Rev Sci Instrum ; 85(2): 02A741, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24593475

RESUMEN

An 18 GHz superconducting electron cyclotron resonance ion source is installed to increase beam currents and to extend the variety of ions especially for highly charged heavy ions which can be accelerated by cyclotrons of Research Center for Nuclear Physics (RCNP), Osaka University. The beam production developments of several ions from B to Xe have been already done [T. Yorita, K. Hatanaka, M. Fukuda, M. Kibayashi, S. Morinobu, H.Okamura, and A. Tamii, Rev. Sci. Instrum. 79, 02A311 (2008) and T. Yorita, K. Hatanaka, M. Fukuda, M. Kibayashi, S. Morinobu, H.Okamura, and A. Tamii, Rev. Sci. Instrum. 81, 02A332 (2010)] and the further studies for those beam extraction and its transport have been done in order to increase the beam current more. The plasma electrode, extraction electrode, and einzel lens are modified. Especially extraction electrode can be applied minus voltage for the beam extraction and it works well to improve the extracted beam current. The extraction voltage dependences of transmission and emittance also have been studied for beam current improvement which is injected into azimuthally varying field cyclotron at RCNP.

18.
Phys Rev Lett ; 108(26): 262501, 2012 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-23004969

RESUMEN

A high-resolution measurement of inelastic proton scattering off (90)Zr near 0° was performed at 295 MeV with a focus on a pronounced strength previously reported in the low-energy tail of giant dipole resonance. A forest of fine structure was observed in the excitation energy region 7-12 MeV. A multipole decomposition analysis of the angular distribution for the forest was carried out using the ECIS95 distorted-wave Born approximation code with the Hartree-Fock plus random-phase approximation model of E1 and M1 transition densities and inclusion of E1 Coulomb excitation. The analysis separated pygmy dipole and M1 resonances in the forest at E(PDR)=9.15±0.18 MeV with Γ(PDR)=2.91±0.64 MeV and at E(M1)=9.53±0.06 MeV with Γ(M1)=2.70±0.17 MeV in the Lorentzian function, respectively. The B(E1)↑ value for pygmy dipole resonance over 7-11 MeV is 0.75±0.08 e(2)fm(2), which corresponds to 2.1±0.2% of the Thomas-Reiche-Kuhn sum rule.

19.
Rev Sci Instrum ; 83(2): 02A335, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22380182

RESUMEN

As the upgrade program of the azimuthally varying field (AVF) cyclotron is at the cyclotron facility of the RCNP, Osaka University for the improvement of the quality, stability, and intensity of accelerated beams, an 18 GHz superconducting (SC) ECR ion source has been installed to increase beam currents and to extend the variety of ions, especially for highly charged heavy ions which can be accelerated by RCNP AVF cyclotron. The production development of several ions such as B, O, N, Ne, Ar, Ni, Kr, and Xe has been performed by Yorita et al. [Rev. Sci. Instrum. 79, 02A311(2008); 81, 02A332 (2010)]. Further studies for the beam transport have been done in order to improve the beam current more for injection of cyclotron. The effect of field leakage of AVF main coil is not negligible and additional steering magnet has been installed and then beam transmission has been improved. The emittance monitor has also been developed for the purpose of investigating correlation between emittance of beam from ECR ion sources and injection efficiency. The monitor consists with BPM82 with rotating wire for fast measurement for efficient study.

20.
Phys Rev Lett ; 107(6): 062502, 2011 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-21902316

RESUMEN

A benchmark experiment on (208)Pb shows that polarized proton inelastic scattering at very forward angles including 0° is a powerful tool for high-resolution studies of electric dipole (E1) and spin magnetic dipole (M1) modes in nuclei over a broad excitation energy range to test up-to-date nuclear models. The extracted E1 polarizability leads to a neutron skin thickness r(skin) = 0.156(-0.021)(+0.025) fm in (208)Pb derived within a mean-field model [Phys. Rev. C 81, 051303 (2010)], thereby constraining the symmetry energy and its density dependence relevant to the description of neutron stars.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...